中空玻璃打胶机泵连续运转并报警的原因及解决!

时间:2019-07-19 来源:http://www.jncsjx.com/ 发布人:昌盛机械

中空玻璃打胶机是现在中空玻璃厂家的常用设备之一了,但是我们在使用中空玻璃打胶机的时候可能会出现很多的情况,其中有一种是中空玻璃打胶机泵连续运转并报警的情况,一般出现这种情况由哪几种原因导致的呢?下面双组分打胶机厂家就给大家分析一下。
Hollow glass gluing machine is one of the common equipment in hollow glass manufacturers, but when we use the hollow glass gluing machine, there may be a lot of situations, one of which is the continuous operation of hollow glass gluing machine pump and alarm. What are the reasons for this situation? The following Shuangzefen glue machine manufacturers will give you an analysis.
原因:胶已用尽。
Reason: The glue has run out.
解决:更换胶桶。
Solution: Replace the rubber drum.
原因:胶桶内有空气,或压不到胶。
Reason: There is air in the rubber drum, or it can't press the glue.
解决:打开压盘上的放气阀,出胶后关闭再打开胶泵上的放气阀,出胶后关闭。
Solution: Open the vent valve on the pressure plate, close the vent valve on the rubber pump after tapping, and close the vent valve after tapping.

双组份打胶机
原因:胶料缸电接点压力表失灵。
Reason: The pressure gauge of the electric contact point of the rubber cylinder is out of order.
解决:更换新的电接点压力表。
Solution: Replace the new electrical contact pressure gauge.
原因:胶泵电机反转。
Reason: Rubber pump motor reversal.
解决:调整胶泵电机相序,重新接线。
Solution: Adjust the phase sequence of rubber pump motor and reconnect.
今天的精彩内容就暂且和大家介绍到这里了,如果大家有其他想要补充的地方,欢迎大家到双组份打胶机的官网给我们留言评论:http://www.jncsjx.com,或者直接拨打我们的咨询热线,我们将给您一个满意的答复!
Today's wonderful content will be introduced here for the time being. If you have anything else to add, you are welcome to leave a message and comment on the official website of the two-component glue machine: http://www.jncsjx.com, or call our hotline directly. We will give you a satisfactory answer!